BOARD NAME | PART NUMBER | REV. | SERIAL NUMBER | CUSTOMER NAME | LOCATION | CATEGORY | STATUS | PRIORITY | FAILURE MODE | REPAIR DURATION |
| START REPAIR | END REPAIR | REPAIR COUNTDOWN | HISTORY | DEFECTIVE DATE | REPAIRED BY | REPAIRED DATE |
DVI_200mA | | E | 251916 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | E | 252425 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | --- failed on verify & checker. Meas ERR. 2V out of range in ch. 0
Corrective Actions :
--- Resoldered colt solder some components and replaced IC U17 (DG444). 9/25/12 | failed since before 2011 | Michael Bayudan | September 25, 2012 |
DVI_200mA | | E | 252370 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | - | 251084 | BECCI | USEA | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | E | 252442 | BECCI | USEA | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250892 | BECCI | BECCI-BRG | DEFECTIVE | ACTIVE | TOP PRIORITY | | 2012-09-18 | 2012-11-18 | -4200 month | --- failed on all diagnostic tests.
--- for ohming and components checking. | | | |
DVI_200mA | | D | 250875 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250864 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | E | 252452 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | E | 250726 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250775 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250861 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | E | 252043 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 251009 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | A | 250596 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | E | 251993 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250730 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | C | 250868 | BECCI | BECCI-BRG | DEFECTIVE | ACTIVE | TOP PRIORITY | | | | | --- failed on all diagnostic tests.
--- open traces in channel 1 and channel 0.
--- this board was upgraded before 200mA to 300mA. | | | |
DVI_200mA | | D | 250687 | BECCI | BECCI-BRG | GOOD | | | | | | | --- failed on all diagnostic tests @ voltage force out of range ch. 0 & 1.
--- possible open circuit.(Gross Failure --- 2 mos).
Corrective Action :
--- replaced IC U7 (LF442cn) and resolder open traces.
--- passed diagnostic tests. 9/27/12 | Failed before 2011 | Michael Bayudan | September 27, 2012 |
DVI_200mA | | D | 251094 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | --- failed on all diagnostic tests.
--- no supply voltage & current in all range (999.999
--- for ohming and components checking
*Corrective Action:
--- found multiple open traces and replaced U4 (LF351N) of Channel 0. Passed All diagnostic tests. Oct. 11, 2012
| Failed before 2011. | Adrian De Leon | Oct. 11, 2012 |
DVI_200mA | | D | 250774 | BECCI | BECCI-BRG | DEFECTIVE | ACTIVE | TOP PRIORITY | | | | | --- failed on all diagnostic tests @ voltage & current is out of range.
--- possible cause defective IC's and open circuits. | | | |
DVI_200mA | | D | 250346 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | * Failed on Ch.1 voltage output.
Corrective Action:
--- found open trace, rewired and resoldered the affected connections. And Passed all diagnostic test. Oct. 19, 2012
| Oct. 2, 2012 | Marlon Sucgang | Oct. 19, 2012 |
DVI_200mA | | D | 250343 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | F | 250307 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | C | 250327 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | A | 250329 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250331 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250342 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250274 | BECCI | BECCI-BRG | DEFECTIVE | | LEAST PRIORITY | | 2013-02-21 | 2013-03-08 | -4090 day | --- failed on verify & checker diagnostic tests @ channel 0 of voltage force out of range / possible cause open circuits. | 2/21/13 | | |
DVI_200mA | | D | 250360 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250386 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | C | 250387 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250389 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250667 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250688 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | * Failed on Ch. 0 Current test.
*Corrective Action :
--- replaced U32 LF412. Passed all diagnostic tests. (Oct. 3, 2012) | Sept.26, 2012 | Michael Bayudan | Oct. 3, 2012 |
DVI_200mA | | D | 250338 | BECCI | BECCI-BRG | DEFECTIVE | ACTIVE | TOP PRIORITY | | | | | --- failed on all diagnostic tests.
--- open traces problem.
--- for ohming and components checking. | failed before 2011 | | |
DVI_200mA | | D | 250676 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250541 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250433 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250418 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250399 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | H | 250694 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250417 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250416 | BECCI | BECCI-BRG | GOOD | ACTIVE | | | | | | | | | |
DVI_200mA | | D | 250414 | BECCI | BECCI-PRODUCTION | GOOD | ACTIVE | | | | | | | | | |